INDEXA question with many inquiries and its reply were summarized from the visitor about PC CPU Unit for MELSEC-Q series.
FAQ NumberAttributeQuestion
[271020]HardWith the Windows NT Embedded 4.0 pre-installation version, at the time of a power supply injection, a screen becomes deep-black and STOP.
[271019]HardAlthough silicon disc PPC-SDD(MS) series and the CD-ROM drive (HDD drive) are used together, CD-ROM drive (or HDD drive) cannot be read.
[271018]HardWhat is the power supply unit which can be used in PPC series ?
[271017]SoftNormal operation is not carried out although Q bus driver was installed by Windows2000.
[271016]HardThe method of power interruption by UPS use ( an example )
[271015]HardPlease let me know the recommendation article of UPS which can be used for a PC CPU.
[271014]HardDo a PC CPU, hard disk, and silicon disc unit occupy I/O point ?
[271013]HardThe parameter error evasion method at the time of multi-CPU composition
( Error code: 3012, 3010 etc. )
[271012]HardPlease let me know notes at the time of multi-CPU system configuration.
[271011]HardAlthough PS/2 splitter (KB-PSY02K3) is connected, NT stops in the middle of a starting screen. Moreover, if a mouse is moved at this time, a buzzer will sound.
( PS/2 mouse is connected to No. 1 of a cable and keyboard is connected to No. 2. )
[271010]HardDo KB-PSY02K2 of PS/2 splitter made from SANWA SUPPLY operate ?
[271009]HardWhat should be inputted although a product key is heard at the time of a pre-installation OS setup ?
[271008]SoftWhat is the support software indicated by the catalog back upper part of a PC CPU unit ? Moreover, unless it uses this, doesn't it operate ?
[271007]SoftCan application development be performed in Windows NT Embedded 4.0 pre-installation model ?
[271006]HardAlthough the circumference use temperature indicated by the catalog is 0-55 degrees C, the circumference use temperature of a hard disk unit is 5-55 degrees C. Does a system configuration top become the numerical value of hard disk unit ?
[271005]HardIs the FPD series made from CONTEC connectable with a PC CPU unit ?
[271004]HardWhat is a serial conversion cable ( PPC-SCC-01 ) ?
[271003]HardCan CD-ROM drive use commercial elegance ?
[271002]HardIn case a bus interface driver is installed, what are required equipments ?
[271001]HardAre the LAN driver and the display driver installed in OS pre-installation model ?


FAQ Number: [ 271020 ] Refix date: 2001.11.28
With the Windows NT Embedded 4.0 pre-installation version, at the time of a power supply injection, a screen becomes deep-black and STOP.
When the Master / Slave setup of the case where BIOS setup of a PC CPU unit is returned to a default, or disk unit are changed by Windows NT Embedded 4.0, OS cannot start normally. Please start the BIOS setup of a PC CPU unit, and change a setup like below. In addition, please refer to a PC CPU unit user's manual ( PPC-CPU686(MS)-MJ ) about the starting method of BIOS setup, or the setting change method.

When disk unit is Master
[Main] =>[Primary Master]
Type:[User]
LBA Mode Control:[Disabled]
[Main] =>[Primary Slave]
Type:[Auto]
When disk unit is Slave
[Main] =>[Primary Master]
Type:[Auto]
[Main] =>[Primary Slave]
Type:[User]
LBA Mode Control:[Disabled]
Adaptation Model
PPC series
INDEX

FAQ Number: [ 271019 ] Refix date: 2001.11.28
Although silicon disc PPC-SDD(MS) series and the CD-ROM drive ( HDD drive ) are used together, CD-ROM drive ( or HDD drive ) cannot be read.
It corresponds to "restrictions at the time of P3 Master / Slave connection" indicated by the PPC-SDD(MS) series explanatory. When this SDD is made into a master, use which makes HDD or CD-ROM a slave cannot be performed.

MasterSlaveEmployment Propriety
SDDHDDImpossible
SDDCD-ROMImpossible
HDDSDDPossible
CD-ROMSDDPossible
SDDSDDPossible
( Notes )
1) Even if it makes into slave SDD in which OS was installed, it makes CD-ROM drive a master and it starts, it starts from C:drive ( SDD ) normally and D:drive ( CD-ROM ) can be read.
2) In Windows NT Embedded 4.0, the combined use with a hard disk needs to make HDD a master.
In order to make it start from SDD of a slave at this time, it is necessary to raise the priority of Slave with the BOOT sequence menu of BIOS, and to correspond with it.
Adaptation Model
PPC series
INDEX

FAQ Number: [ 271018] Refix date: 2001.11.28
What is the power supply unit which can be used in PPC series ?
The power supply unit of the following kinds can be used.
Q61P-A1:AC100-120V Input / DC5V 6A Output
Q61P-A2:AC200-240V Input / DC5V 6A Output
Q63P:DC24V Input / DC5V 6A Output
Q64P:AC100/200V Input / DC5V 8.5A Output

The power supply unit which cannot be used.

Q62P:AC100-240V Input / DC5V3A,DC24V/0.6A Output
* Since more than DC5V 6A is required for a power supply unit, Q62P (DC5V 3A) do not get used to use.
Adaptation Model
PPC series
INDEX

FAQ Number: [ 271017] Refix date: 2001.11.28
Normal operation is not carried out although Q bus driver was installed by Windows2000.
The following is indicated by PPC-DRV-01 explanatory.

In the case of Windows2000, in addition to installation which is PPC-DRV-01 (utility), PPC-DRV-01 (driver *1) needs to be installed.
 *1 In NT4.0, installation of "driver" is unnecessary.

1) installation of a utility: Explanatory P12( 4.1.2.(19) ) => required of NT4.0 and Win2000
Execution of Setup.exe in CD-ROM
2) Installation of the driver for 2000: Explanatory P15( 4.1.2.(2) ) => Necessary at Win2000. Unnecessary at NT4.0.
Control panel => System => Hardware = > Device manager
=> PCI Bridge device of others => Whole is chosen and it is re-installation of a driver
=> to the next ( 3 times )
=> D:Input \disk7Win2000\JP and OK => Next => OK
=> Input \disk7Win2000\JP into a copied material and OK.
=> reboot Device manager
=> Q Series Bus Insterface can be checked.

Adaptation Model
PPC series
INDEX

FAQ Number: [ 271016] Refix date: 2001.11.28
The method of power interruption by UPS use ( an example )
Combined use with UPS
 UPS is used for the power supply of a PLC base, and it connects with a PC CPU, and if the power supply management software for a shutdown is used (RS-232C etc.), the power supply OFF after a shutdown will be processed automatically.
 If the primary power supply of UPS is severed, UPS will be changed to a backup power supply and a shutdown command will be published from UPS to a PC CPU (RS-232C etc.). If a shutdown is completed with a PC CPU, the notice of completion is published to the UPS side, and UPS turns off the backup power supply by the side of secondary. Therefore, if the main breakers etc. are set as the primary UPS power supply, it can turn off automatically only by turning off a breaker.
 However, a time lag occurs until a PLC power supply is turned off from Breaker OFF.
Adaptation Model
PPC series
INDEX

FAQ Number: [ 271015] Refix date: 2001.12.26
Please let me know the recommendation article of UPS which can be used for a PC CPU.
To the PLC base power supply which used the PC CPU, the following UPS by Mitsubishi Electric Corp. serves as a recommendation article. Mitsubishi UPS "FREQUPS" V/A series In addition, FREQUPS-F series cannot be used.
Moreover, UPS of a rectangle wave output cannot use the power supply unit for PLC.
Please refer to the homepage of Mitsubishi Electric Corp. for the details of FREQUPS series. http://www.mitsubishielectric.co.jp/frequps/

[ Reference ] Power supply unit which can be used in PPC series => FAQ [271018]

Adaptation Model
PPC series
INDEX

FAQ Number: [ 271014] Refix date: 2001.11.28
Do a PC CPU, hard disk, and silicon disc unit occupy I/O point ?
I/O allotment is not occupied only by PPC-SDD(MS) series and PPC-HDD(MS)-5 using a slot.
It is possible to set it as zero point with a parameter. (When not setting up, it is set as one slots 16 as an empty slot.) In addition, by parameter setup, although a CPU unit occupies 2slots physically, since it is recognized as 1slot, please give 2 slot eye as empty slots ( I/O un-occupying or 16 defaults ).
Adaptation Model
PPC series
INDEX

FAQ Number: [ 271013] Refix date: 2001.11.28
The parameter error evasion method at the time of multi-CPU composition
( Error code: 3012, 3010 etc. )
At the time of multi-CPU composition, it is foundations to divert the multi-CPU parameter file created by GX Developer by PLC CPU side. ==> Detailed data STI01B02-PPC-R01.pdf ( PDF form: 139KB ) Adaptation Model
PPC series
INDEX

FAQ Number: [ 271012] Refix date: 2001.12.26
Please let me know notes at the time of multi-CPU system configuration.
The following is indicated by PPC-DRV-01 explanatory PIII.
A) When you build the multi-CPU system which used the PC CPU unit, as for PLC CPU, 5 figures should use QCPU ( Q mode ) after "03051" on the functional version B and serial No.
B) When you build the multi-CPU system which used the PC CPU unit, Motion CPU should use the product after following serial No.

  • Q172CPU -- 1 figure is after "H" on serial No.
  • Q173CPU -- 1 figure is after "G" on serial No.

  • C) The multi-CPU parameter set up in the PC CPU unit cannot be diverted to QCPU ( Q mode ) in the same system. Please divert the multi-CPU parameter set up by QCPU ( Q mode ).
    Adaptation Model
    PPC series
    INDEX

    FAQ Number: [ 271011] Refix date: 2001.11.28
    Although PS/2 splitter (KB-PSY02K3) is connected, NT stops in the middle of a starting screen. Moreover, if a mouse is moved at this time, a buzzer will sound.
    ( PS/2 mouse is connected to No. 1 of a cable and keyboard is connected to No. 2. )
    Please check whether SW-6 of the DIP switch of PPC-CPU686(MS) main part are turned on. ( Explanatory PPC-CPU686(MS)-MJ P32 )
    It is turned off it at the time of shipment, and DIP switch SW-6 have become PS/2 keyboards only. If PS/2 splitter ( KB-PSY02K3 SANWA SUPPLY ) is used at the time of this setup, the above-mentioned phenomenon will occur.
    Adaptation Model
    PPC series
    INDEX

    FAQ Number: [ 271010] Refix date: 2001.11.28
    Do KB-PSY02K2 of PS/2 splitter made from SANWA SUPPLY operate ?
    Type of K2 does not operate. Please specify KB-PSY02K3. Adaptation Model
    PPC series
    INDEX

    FAQ Number: [ 271009] Refix date: 2001.11.28
    What should be inputted although a product key is heard at the time of a pre-installation OS setup ?
    The license sticker of OS is stuck on hard disk unit PPC-HDD(MS)-5, and the product key is indicated there. Adaptation Model
    PPC series
    INDEX

    FAQ Number: [ 271008] Refix date: 2001.12.26
    What is the support software indicated by the catalog back upper part of a PC CPU unit ? Moreover, unless it uses this, doesn't it operate ?
    EZSocket is communication middleware of the Mitsubishi FA apparatus which Mitsubishi Electric advocates. The partner who has indicated contracts with Mitsubishi Electric and is doing manufacture sale of the application software based on the exhibited EZSocket specification.
     If it corresponds to EZSocket of the following version, it will introduce from a solution spreading more in the meaning that the application software of each company operates in a PC CPU unit.
     In addition, at least the application with which such application software was not used but the visitor was created can be operated.
    Adaptation Model
    PPC series
    INDEX

    FAQ Number: [ 271007] Refix date: 2001.11.28
    Can application development be performed in Windows NT Embedded 4.0 pre-installation model ?
    Since Windows NT Embedded 4.0 is OS of an inclusion use, this OS loading machine serves as the employment purpose instead of an application development use.
    Therefore, I will have Windows NT 4.0 machine perform application development separately, and the completed application will be employed by the Windows NT Embedded 4.0 loading machine.
    Adaptation Model
    PPC series
    INDEX

    FAQ Number: [ 271006] Refix date: 2001.12.26
    Although the circumference use temperature indicated by the catalog is 0-55 degrees C, the circumference use temperature of a hard disk unit is 5-55 degrees C. Does a system configuration top become the numerical value of hard disk unit ?
    System configuration top follows specification with lower environmental specification. Therefore, when using a hard disk unit, the circumference temperature as a system configuration becomes 5-55 degrees C.
    In addition, this corresponds also to the environmental specification as the whole system at the time of equipping with option articles ( Floppy disk disk drive, CD-ROM drive, etc. ) or commercial peripheral equipment ( PC card, USB apparatus, keyboard, etc. ).
    Adaptation Model
    PPC series
    INDEX

    FAQ Number: [ 271005] Refix date: 2001.11.28
    Is the FPD series made from CONTEC connectable with a PC CPU unit ?
    Three models is connectable Panel mount type Analog RGB input type ( with Touch panel ) following.
    IPC-DT/M20V(PC)TTFT color 10.4" VGA( 640 x 480 dots )New product
    IPC-DT/L20S(PC)TTFT color 12.1" SVGA( 800 x 600 dots )New product
    IPC-DT/H20X(PC)TTFT color 15" XGA( 1024 x 768 dots )New product
    Other FPD series ( Digital / Panel link ) is not connectable.
    Adaptation Model
    PPC series
    INDEX

    FAQ Number: [ 271004] Refix date: 2001.11.28
    What is a serial conversion cable ( PPC-SCC-01 ) ?
    It connects with the extended interface ( EX.I/F ) of a PC CPU unit, and is used as a serial port of 2 port watch. Although a connector terminal ( PPC-COT-01 ) can be connected to an extended interface ( EX.I/F ) and Parallel port / serial port / USB port / Terminal stand can be extended, if it is only addition of a serial port, please use this serial conversion cable. Adaptation Model
    PPC series
    INDEX

    FAQ Number: [ 271003] Refix date: 2001.11.28
    Can CD-ROM drive use commercial elegance ?
    Since IDE connector portion is special form, please use an exclusive option CD-ROM drive ( PPC-CDD-01 ). Adaptation Model
    PPC series
    INDEX

    FAQ Number: [ 271002] Refix date: 2001.11.28
    In case a bus interface driver is installed, what are required equipments ?
    There are two kinds of methods as follows, and required equipments also differ. In addition, a PC CPU unit, a base unit, and a power supply unit are needed in addition to the following equipments.
    1) Installation from CD-ROM drive
    CD-ROM drive ( PPC-CDD-01 )
    Display
    Keyboard
    Mouse(*1)
    KB-PSY02K3 ( PS/2 splitter by the SANWA SUPPLY company )(*1)
    2) Installation from Floppy disk drive
    Floppy disk drive ( PC-FDD25BH )
    Display
    Keyboard
    Mouse(*1)
    KB-PSY02K3 ( PS/2 splitter by the SANWA SUPPLY company )(*1)
    *1: When the operativity of various setup after installation of bus interface driver and installation is considered, a mouse and KB-PSY02K3 are required.
    Adaptation Model
    PPC series
    INDEX

    FAQ Number: [ 271001] Refix date: 2001.11.28
    Are the LAN driver and the display driver installed in OS pre-installation model ?
    Although LAN driver and display driver are installation ending, please change a property setup of IP address, resolution, etc. according to the environment to be used, for example. Moreover, since the bus interface driver ( PPC-DRV-01 ) is not installed, please perform installation from an after purchase CD-ROM drive (option). Adaptation Model
    PPC series
    INDEX