===================================================================== = CPS-MG341 Series Firmware Upgrade = = CPS-MG341 Series firmware Ver3.8.0 = = CONTEC Co.,Ltd. = ===================================================================== ◆ Table of Contents ======= Introduction Before upgrading Version upgrading procedure Version upgrading history ◆ Introduction =========== Thank you for your continued patronage of CONTEC products. This describes the additional information of CPS-MG341 series firmware upgrade. For how to use the product, please visit our website and see the system setup guide. (http://www.contec.com) ◆ Firmware upgrading precaution =========== *Do not downgrade the firmware. *The required time for upgrading CPS-MG341-ADSC1-931: about 15 minutes other models: about 40 minutes *********************************************************************** * Do not turn off the power when LED ST1 and ST2 are on. * * Doing so may break the data and device will be unable to boot. * *********************************************************************** * The former task program (1.0.6f or earlier) will convert and run in the .2.0.0 and later version. However, the screen that was created in the former monitoring (1.0.6f or earlier) cannot be used. The screen needs to be created again with new tools. ◆ Before upgrading =========== Have the followings ready ・Product (CPS-MG341 series) ・Host computer ・LAN cable ・Firmware upgrade file ◆ Version upgrading procedure =========== 1.Turn on the power of the CPS-MG341 product. 2.Connect the product to a host computer with a LAN cable. 3.Access the product via web browser from the computer. If the CPS-MG341 still has the default setting, set the host computer on the same network (e.g.:10.1.1.102) and enter "http://10.1.1.101" in URL. If you are uncertain of your IP address, the default settings (10.1.1.101) can be restored temporarily by turning on the power with SW1-2 switch on. 4.Log in the product. You will be asked to enter a user name and a password. Enter them and click "OK" button. 5.Follow the instruction below to go to "Firmware version up" menu. -The curent firmware version v2.XX In the "Status nemu", click "Maintenace menu", and then "Firmware version up"in the Backup group. Click "Browse" button. Specifiy the file in the host computer to upload. Click "upload" button. -The curent firmware version v3.XX In the "Memu", click "Firmware Version Up" in the Maintenace group. Click "Browse" button. Specifiy the file in the host computer to upload. Click "Update" button. *If the firmware upgrade file is compressed (extension:zip), decompress it before uploading(extension:bin). 6.Upgrading will start and the product will be rebooted. LED display changes as described below. Upgrading ①PWR on, ST1 flashing (slow), ST2 off ②PWR on, ST1, ST2 flashing (fast) ③PWR on, ST1, ST2 off ④PWR on, ST1, ST2 flashing (slow) Rebooting ⑤PWR, ST1, ST2 on ⑥PWR on, ST1, ST2 off ⑦PWR on, ST1 flashing (slow), ST2 off 7.After rebooting completes, check the version. Access the product via web browser again. From "Menu", click "System" under the group of Status. ◆ Version upgrading history =========== Ver3.8.0 -------------------------------- - Added the following vulnerability countermeasures. 1. OS Command Injection Vulnerability In the following page, the entered value is not properly validated, which makes it possible to execute OS commands. [Network] maintenance page [Mail] setting page [Static Routing] setting page [Port Forwarding] setting page [IP Filter] setting page 2. Firmware tampering vulnerability Firmware structure can be analyzed due to insufficient cryptographic strength of firmware update files. 3. Vulnerability to inadequate access restrictions Network maintenance page originally accessible only with administrator privileges can be accessed with normal privileges. Ver3.7.10 -------------------------------- - The support for the BACnet client function started. - Added protocol setting to port forwarding function. Problem Fix - Router function cannot be set due to timing of activation of 3G network. - Deleting a file on the FTP server, but still receiving the previous file. - VTC processing proceeds even though FTP reception has not been completed. - VTC was updated (ver1.84 to ver1.85). For details, refer to “Online Help”. Ver3.7.9 -------------------------------- - The support for the BACnet server function started. - The function to set startup data was added to the TAG settings of the tag edit function. Product concerned : CPS-MG341G5-ADSC1-931 Problem Fix - MQTT service stops after disconnecting from server. - PLC communication process terminates abnormally when communicating with PLC. PLC concerned: Panasonic PLC FP7 series - For data transmission function, the probability that transmitted data may remain depending on the device settings. - VTC was updated (ver1.83 to ver1.84). For details, refer to “Online Help”. Ver3.7.8 -------------------------------- - The support for the router function started. DHCP server, static routing, port forwarding, and IP filter functions were added. Ver3.7.7 -------------------------------- Problem Fix - Cloud backup folder is not compressed. Ver3.7.6 -------------------------------- - Changed the number of TOPICs for MQTT publish/subscribe to a maximum of 16. - Added "1 min" setting item to Cycle of LTE Alive Monitoring on the LTE setting. - Added "2: SD card error" and "3: write error" for "SD Recognition" in Modbus status. - The functions “Forced Reboot” and “Repair SD and Reboot” were added. Problem Fix - CHS settings are not reflected when Data Transfer Service is restarted. - In the tag edit function, the "%" character is empty when registered as a STAG. - For READ requests in PLC MITSUBISH 4C ASCII communication, different response data may be received for the request. - Modified so that data transmission can continue even if SD is in an error state when "Auto Backup" is enabled in the Data Transfer setting. - VTC was updated (ver1.82 to ver1.83). For details, refer to “Online Help”. Ver3.7.5 -------------------------------- - Changed the method for transmitting blank data to Azure. - For the "Auto Backup Folder", when there is no free space on the SD card when creating a new compressed file (YYYYMMDD.tgz), added the process of deleting the oldest compressed file to free up space. - The support for the PLC Mitsubishi MELSEC Q/IQ-R/IQ-F series Ethernet communication 4E ASCII started. - Rebooting function for NTP time synchronization service was added. Problem Fix - If the comments in the configuration file are empty characters, the text doesn't disappear after restoring the TAG information. - MQTT tag setting is not initialized by DIP switch. - After importing the publish/subscribe data settings in the MQTT publish/subscribe screen, the wrong PLC device is set in the "Category" item. - VTC was updated (ver1.80 to ver1.82). For details, refer to “Online Help”. Ver3.7.4 -------------------------------- Problem Fix - The first MQTT transmission by VTC does not work. Ver3.7.3 -------------------------------- - Changed 100msec interlock of scan interval to 10msec in PLC device settings. - The LED control processing for shutdown by the MCS341 series power switch is integrated with the processing by the MC/MG341 series shutdown switch. - Added Expansion SDK Add custom type [file]. - Add a function to terminate the process of writing to the SD card when updating. - Add a process to write unprocessed data in the cache to the SD card when updating. Problem Fix - Expansion SDK was fixed Cannot remove or edit options of custom programs for startup if they contain the "/" character. Unable to get local time in custom program. - In PLC TCP communication, communication becomes impossible depending on the connection disconnection method of the other device. - Improved processing of PLC Ethernet communication when receiving data. PLC concerned: OMRON SYSMAC Series MITSUBISIHI MESLSEC Series - Reviewed the process of receiving READ requests for ASCII communication for Mitsubishi Q/IQ-F/IQ-R Series. Ver3.7.2 -------------------------------- - Changed the method for transmitting Japanese data to Azure. - The function was added to the product 3G model(CPS-MG341G-ADSC1-930) and LTE model(CPS-MG341G5-ADSC1-931). Added a setting to enter the PIN code if the SIM is locked. Added AT command history on the log page. - Added settings for Mitsubishi MELSEC FX Series PLCs. Communication method : Ethernet Format : BINARY - Added a function to restart the device when kernel panic occur. Problem Fix - Fix CHS function below "Cloudkey" can't be registered when a new tag is added to it. - Parentheses, "(" and ")", can't be used for password on 3G setting. - Communication is not performed correctly for multiple channels of bit devices when the PLC communication settings are as follows. OMRON SYSMAC CS/CJ/CP Series Serial/Ethernet communication. - Fixed startup process of CPS-MG341G-ADSC1-930. - OMRON SYSMAC CS/CJ/CP Series serial communication. Improved processing when requesting a READ Specifying the station number - Fix the process of restart 3G module. model: CPS-MG341G-ADSC1-111 - VTC was updated (ver1.79 to ver1.80). Baudrate:460800 bps can be selected from serial setting of "Link setting". For details, refer to “Online Help”. Ver3.7.1 -------------------------------- - Added the function to reassign the IP address when the IP address of the wired LAN (eth0) is lost. - Changed the restoring function to restore the specified or all items. - The device file that can be used in the expansion SDK custom program was added. Problem Fix - Buffer clearing process before making a request to PLC was added. - The input format notation for the start address and the end address were not displayed on the PLC page. - Station number settings were not reflected during serial communication with the PLC of the KEYENCE. - Timeout and Retry settings were not reflected during serial communication with the TYOPUC. - VTC was updated (ver1.78 to ver1.79). For details, refer to “Online Help”. Ver3.7.0 -------------------------------- - The support for the LTE and SMS functions started (the CPS-MG341G5-ADSC1-931). - The industrial value conversion function for analog input values was added (the CPS-MG341-ADSC1 Series models). Ver3.6.2 -------------------------------- - The backup function was added. SD card was added as a destination to download the backup file to. The name of the backup file was changed. - SMS function was added to the product 3G model(CPS-MG341G-ADSC1-930). - The restoring function was changed to restore the specified items. - Functions for FTP were added. Files are able to be sent and received to and from multiple FTP servers. The prohibited character "." to be used in the middle of a folder name was changed to a permitted character. - The number of characters for a password was increased. (30 to 64 alphanumeric characters) in the [Mail] setting page. - The amendable sections were increased in Link config, CPU config, and DEVICE config of PLC setting. - On the [Time] setting page, the function was changed to write the time in temporary storage space and RTC by clicking the “Update” button. - The settings of the "Server Connection Timeout" and the "Data Transfer Timeout" were added in the [Data Transfer] function and the[FTP Put] function. - OMRON PLC CS / CJ series device (extended data memory) was updated. - The number of characters for a client ID was increased. (23 to 256 alphanumeric characters) in the [MQTT Connection] page. Problem Fix - The pull-down menu did not appear in the PLC page when accessed from IE11. - The Data Transfer Service did not perform. - The values of VTC "Batch Read" control and "Batch Read (Str)" control were sometimes unable to be viewed properly. - The system was unable to communicate with the OMRON PLC CP series - The system was unable to communicate with the OMRON PLC C series. - Setting up the Data Transfer Service generated file names with wrong dates. - VTC was updated (ver1.77 to ver1.78). For details, refer to “Online Help”. Ver3.6.1 -------------------------------- Problem Fix - Unnecessary DNS queries were sent to the 3G network. Ver3.6.0 -------------------------------- - For FTP function, made the folder hierarchy settable from VTC. - The support for the PLC Mitsubishi MELSEC FX series file register (R) started. - The setting of the PLC Mitsubishi MELSEC IQ-F series was added. Comm method: Ethernet Format : Binary Frame : 3E - The support for the PLC Mitsubishi series Ethernet UDP communication started. - The setting item (Connection source port number) in the PLC Ethernet UDP communication was added. - The setting of NTP synchronization time became available. - The functions in MQTT Client were added. The number of MQTT publish/subscribe data were increased up to 3000 for each cloud key. The support for CSV import/export for the data settings in MQTT publish/subscribe were added. Enable and disable functions for each data in MQTT publish/subscribe were added. Two types for the publishing options in MQTT publish setting were added. Changed for cloud key to be specified when STAG is set for payload in MQTT subscribe setting. Rebooting function for MQTT service was added. - Modbus Slave function The support for the single holding register writing (function code : 0x06) started. The register range : for reading/writing of PLC communication data (0x2000 - 0x47FF) - Areas for Modbus holding register were added. For reading/writing of PLC communication data (0x2000-0x47FF) - Modbus area web monitoring function/writing function were added. - The support was added for the extension SDK USB serial device to be controlled by custom program. - The bit address setting of PLC KEYENCE and PANASONIC were changed to be set with the same input method as OMRON’s - HMI was updated (ver2.18.0 to ver2.18.1). For details, refer to "Online Help". - VTC was updated (ver1.76 to ver1.77). For details, refer to "Online Help". Problem Fix - The PLC of Mitsubishi MELSEC FX series had bugs. Comm method : Ethernet Format: ASCII Frame : 1E Device: Step relay(S) - Values of PLC device setting were displayed incorrectly. Maker: MODBUS Device type: InputStatus, InputRegister - The MQTT bug-fixed as follows: The check process upon uploading the certificate on MQTT connection setting screen. Upon starting up MQTT Client, a connection started to the Broker before time setting has been completed. - OPC UA did not work when using Link local address. - Data were sent in a different format file from the specifications in the data transfer function. - An additional letter was added when selecting [CR+LF] in VTC log control. - The following data were not deleted even when they were kept longer than three days. Send Folder (Azure) Send Folder (Mail) Send folder(FTP) Send Folder (Task-CHS) Resend Folder (Azure) Resend Folder (Mail) Resend folder(FTP) Resend Folder (Task-CHS) - Blank data were occasionally sent. Data Transfer Service PLC Data Transfer VTC cloud transmission Ver3.5.0 -------------------------------- - MQTT Client function was added. - Specifying and function for destination service were added in data transfer settings. - New support for wireless LAN USB was available. - HMI was updated (ver2.17.1 to ver2.18.0) For details, refer to “Online Help”. - VTC was updated (ver1.72 to ver1.76) For details, refer to on“Online Help”. Problem Fix - List cannot be displayed on Tag edit screen when accessing from IE11 - The number ofcharacters that can be entered in the Start address and End address in PLC setting was changed to 7 characters - Operation stops after setting time in PLC communication. Ver3.4.3 -------------------------------- Problem Fix - The controller does not operate properly in Modbus RTU depending on the settings. Ver3.4.2 -------------------------------- - Support for the PLC OMRON SYSMAC CP series started. - New assignments (0x7000 to 0x74FF) for Modbus Status Information (Gateway information) were added. For details, refer to "Reference Manual (Software) Appendix 6. Modbus Status Information". - The number of configurable items listed below for PLC setting was increased. CPU : 30 to128 Device : 100 to 256 (the number of configurable devices) - Displaying a warning popup was added when the pre-set user password is remained as the default settings. - The format of Node Tree displayed in the address space of the OPC UA client was changed. CPS-MC341-ADSC to CPS-MG341-ADSC1 - The number of characters that can be entered in the option of the ROMSDK custom program edit screen (16 characters to 100 characters) was increased. - Help for TAG editing was added. - HMI was updated.(ver2.17.0 to ver2.17.1) For details, refer to “Online Help”. - VTC was updated.(ver1.70 to ver1.72) For details, refer to “Online Help”. Problem Fix - Station number for writing to HoldingRegister is fixed at 1 in PLC MODBUS RTU communication. - For Azure transmission, the files are divided to send if the file size is 1023 bytes or greater. Ver3.4.1 -------------------------------- - Service Restart supports. Data Transfer, PLC, 3G, 920MHz, OPCUA - Added OPC UA functions. The Listen port is able to be edited. The Response Address is able to be edited. The Anonymous Connection is able to be valid or invalid. - HMI update (ver2.16.8→ver2.17.0) Refer to Online Help for details. - VTC update (ver1.61→ver1.70) Refer to Online Help for details. - Added Panasonic PLC series. Refer to HP, List of supported PLCs equipment, for details. - KEYENCE PLC series support. Refer to HP, List of supported PLCs equipment, for details. - TOYOPUC PLC series The size of Bit Write/Read for extended area is changed from 1 bit to variable. - Setting Range and Defalut Value for PLC settings are changed. Setting Range: Timeout (sec) Retry Number Default Value: Cloud Interval (sec) Problem Fix - TAG Edit 4 byte characters were not able to be changed in Binary value. The pop-up for help was not displayed correctly sometimes. - Setting value more than 128 words was not displayed WEB setting. - User/Password setting If User Name has only number, it can't be deleted. - Setting Range for FTP setting is changed. FTP host name (address), User - Displayed each MAC address (eth0, eth1) of the model below. CPS-MG341-ADSC1-931 CPS-MG341G-ADSC1-930 - OMRON PLC Ethernet It cannot be communicated depends on PLC IP address. - In the setting item (data format) of PLC setting, 32-bit signed was described as 32-bit unsigned on the English display. Ver3.3.2 -------------------------------- Problem Fix - Setting range of the setting below was changed. Wireless LAN: Encryption Key WPA ... 8-63 alphanumeric characters and symbols except space( ), linefeed(CR+LF),double quotation mark("),single quotation mark('), backslash(\) and backquote(`), or 64-digit hexadecimal number - Expansion SDK was fixed Custom program was not excuted in the boot process Custom program was not saved to SD Ver3.3.1 -------------------------------- Problem Fix - if aploaded a file which has space in name in HMI, ROM remaining capacity was not correctly checked. - ROM remaining capacity was increased by changing file structure. - VTC update (ver1.60→ver1.61) Refer to Online Help for details. - In MODBUS TCP/RTU settings, the probability that the communication did not work properly. Ver3.3.0 -------------------------------- - Panasonic PLC FP7 series Ethernet(MEWTOCOL-COM,MEWTOCOL-DAT) support. Refer to HP, List of supported PLCs equipment, for details. - Added Expansion SDK Refer to 'Reference Manual:CONPROSYS Expansion SDK' for details. - VTC update (ver1.42→ver1.60)s Refer to Online Help for details. Ver3.2.1 -------------------------------- - Panasonic PLC FP7 series Serial(MEWTOCOL-COM) support. Refer to HP, List of supported PLCs equipment,for details. - Added TAG Edit function TAG information import/export - HMI update (ver2.16.2→ver2.16.8) Refer to Online Help for details. - VTC update (ver1.41→ver1.42) Refer to Online Help for details. Problem Fix - Modified to link set per series in Mitsubishi MELSEC in PLC setting. (Former) Maker: MELSEC-A series/ MELSEC-Q series (Current) Maker: MELSEC-A series/ MELSEC-A series A1SJ/ MELSEC-A series AJ71/ MELSEC-Q series/ MELSEC-FX series/MELSEC iQ-F series/MELSEC iQ-R series - Modbus status information: Timer (100ms) in specialized functions was unable to operate properly. - In 3G setting, the probability that the product freezes when the 3G alive monitoring is enabled. Product concerned : CPS-MG341G-ADSC1-930, CPS-MG341G-ADSC1-111 - In MODBUS communication of PLC, sum check was unable to perform properly. Ver3.2.0 -------------------------------- - Added the VTC functions in CONPROSYS series The number of task pages to be saved is increased. Tasks in up to 20 pages are able to be edited, saved, and debugged. Increased TAG and STAG functions TAG and STAG variables are increased up to 500. The following functions are added. Comment setting Display function Monitoring function Comment display function is added in HMI and VTC. The operation status graph is added in HMI graph item. Increased the user management function Limitations on the functions for a general user are changed.(Administrator only) - Wireless LAN encryption support (NONE,WEP,WPA-PSK(AES),WPA-PSK(TKIP),WPA2-PSK(AES),WPA2-PSK(TKIP),WPA/WPA2-PSK(AUTO)) - Modified to update the RTC time after the completion of NTP time synchronization. Problem Fix - The probability that WEB setting screen was not displayed properly when using Internet Explorer. - The probability that the wireless LAN was not linked properly. - The probability that PLC serial communication does not work properly when its settings are newly added. Ver3.1.5 -------------------------------- Problem Fix - The probability that proper communication is disturbed due to the PLC settings. PLC concerned: OMROM PLC Ethernet BINARY FINS Ethernet - PLC communication process stopped when the product with PLC settings was unable to communicate to PLC for an extended period of time. PLC concerned: MITSUBISHI PLC Ethernet ASCII 1E MITSUBISHI PLC Ethernet ASCII 3E TOYOPUC Ethernet MODBUS TCP - A correct value was not displayed in "System information: The size of file xx at the present time". Ver3.1.4 -------------------------------- Problem Fix - Communication was unable to restart after reconnecting LAN cable. PLC concerned: MITSUBISHI PLC Ethernet ASCII 1E MITSUBISHI PLC Ethernet ASCII 3E OMROM PLC Ethernet BINARY FINS Ethernet - Timeout and Retry were unable to function properly in PLC settings. PLC concerned: MITSUBISHI PLC Ethernet ASCII 1E MITSUBISHI PLC Ethernet ASCII 3E MITSUBISHI PLC Ethernet BINARY 3E OMROM PLC Ethernet BINARY FINS Ethernet OMROM PLC Ethernet BINARY FINS Serial - The probability that communication with PLC is unable to start due to network settings (IP address) in CONPROSYS. PLC concerned : OMROM PLC Ethernet BINARY FINS Ethernet - Modified to send a command to end PLC communication upon rebooting through the WEB setting screen. - The probability that a wrong calculation result from VTC calculation parts is returned. Ver3.1.3 -------------------------------- Problem Fix - The probability that some section of measured data disappears from the file (.csv) in resend folder. - The storage period of the resend file was changed. Period : two days to three days. Ver3.1.2 -------------------------------- Problem Fix - The problem which the files remain in "Send Folder(Azure)" when more than 2 process of "Send Azure IoT" on VTC are excuted at the same time. - The problem which the PLC communication will be stopped by reconnecting the LAN. Maker: MITSUBISHI Communication Method: Ethernet Format: BINARY Frame: 3E Ver3.1.1 -------------------------------- Problem Fix - After the device is activated, there is a problem with LAN A (eth0) about the network connection. Model:CPS-MG341G-ADSC1-111 - "Link Name", "CPU Name","Device Name" on the PLC setting page, each of them which is set as out of setting range below can be deleted and changed. Setting Range:1-32 alphanumeric characters, underline(_) and hyphen(-). Ver3.1.0 -------------------------------- - TOYOPUC Ethernet communication extended command-compatible (K1,V1,TC1,L1,X1,Y1,M1,S1,N1,R1,D1,B1,K2,V2,TC2,L2,X2,Y2,M2,S2,N2,R2,D2,B2,K3,V3,T3,L3,X3,Y3,M3,S3,N3,R3,D3,B3,EB_9,EB_A,EB_B,EB_C) - WEB setting screen: Display of address in Modbus is unified in hex. Problem Fix: - TOYOPUC Ethernet communication EB command fixed EB → EB_9,EB_A,EB_B,EB_C - When specific string was in STAG, it was unable to be displayed on HMI. - Tasks became unstable when using variables in VTC operaon. - When writing with F&eIT protocol into a device, it shoultid response by 0x40 if the resource of queue was insufficient. - The “Open from local disk”in HMI&VTC was unable to operate in Firefox 61 or later versions. - Modified the contents of VTC system information. (LINK -> CPU、Device group -> DEVICE、 DEV ->DEVICE) - "FANUC CNC" added to VTC for CPS-MG341G-ADSC1-930. - WEB setting screen: Modified the unit of timeout in PLC CPU setting. - Modified the following settings on WEB setting screen Setting range: Domain name to Domain name[0 to 128 of one-byte alphanumeric letters, hyphen (-), and dot (.)] 3G: APN Time: NTP server FTP: FTP host name Mail: SMTP server Ver3.0.9 -------------------------------- - Station number was added to the setting below. Maker :MODBUS Communication Method :Ethernet * It is set to 1 for the old version - Top page will be shown properly if move to the old page for Ver.2XX. - The setting page refers to a browser's setting for langugage. Problem Fix - OMRON PLC can be set by each series. Series name:C,CS,CJ - If Link, CPU and Device Name of PLC setting is coincident with the partial character string at the front from the each other setting names, PLC communication doesn't work properly. - The number is assigned for Link, CPU, Device on the PLC setting. - The part of Gateway Information of VTC is modified as below. LINK01~LINK10 → CPU01~CPU10 - The status of CPU and Device is not updated correctly. Ver3.0.8 -------------------------------- Problem Fix - BuiltInPowerState of Modbus status(0x5023) is not updated based on the setting. - LAN B doesn't work properly for CPS-MG341G-ADSC1-930. - Digital Input Power is not changeable internal or external power for CPS-MG341G-ADSC1-930. Ver3.0.7 -------------------------------- Problem Fix - PLC communication doesn't restart when PLC is reset. - OPC UA and MTConnect service don't work properly for CPS-MG341G-ADSC1-930. - Modbus status value is not gotten properly by the link setting of HMI. Ver3.0.6 -------------------------------- Problem Fix - CONNECTION STRING of Azure setting can not be set properly. - Digital Filter of Device setting does not work properly. - Compressed file(.tgz) is not shown from Auto Backcup Folder. Ver3.0.5 -------------------------------- Problem Fix: - TOYOPUC PLC Ethernet  Scan interval is not set correctly. - ROM capacity is not correctly shown on HMI. - Modified to check ROM capacity when settings are saved from HMI. Ver3.0.4 -------------------------------- Problem Fix: - Communication data was partially lost in Mitsubishi PLC[QJ71C24N(4C4).lin] serial communication. - NTP result are not correctly stored in Modbus address(0x5000~) after synchronization with NTP server. - Deleted YOKOGAWA PLC from the list due to currently unsupported. Ver3.0.3 -------------------------------- - Modified to check ROM capacity when settings are saved and firmware is updated. Problem Fix: - Link setting was unable to be performed properly in PLC setting. - Communication data was partially lost in Mitsubishi PLC[QJ71C24N(4C4).lin] serial communication. Ver3.0.2 -------------------------------- - Change the process of extracting file. - On network confirmation page, change to clear the log file before executing each command. Problem Fix - In DIP switch setting, some initializations were unable to be done properly. - On mail setting page, multiple registration of mail address by separating with comma was unable to be done. - Some MTConnect settings from Web browser were unable to be done. Ver3.0.1 -------------------------------- Problem Fix: - On PLC setting page, some CPUs and devices for Master were unable to be registered. - On PLC setting page, CPUs and devices were unable to be deleted when Master did not exist. Ver3.0.0 -------------------------------- - VTC update (ver1.21→ver1.30) -Calculating control was added. -For system information control, the contents such as serial number were added. - HMI update (version 2.12 to 2.14) -Refer to Online Help for details. - Upgrade WEB setting screen -Digital filter setting function was added for the ADSC1 model device setting. -PLC Setting pages Problem fix: - The system shuts down when using TP link driver (8188eu). - Updating stops when connecting through wireless LAN. - String calculation control of VTC worked differently from the previous version. Fixed: Insert an empty string into STAG when number of characters to extract is beyond the specified scope or 0. - Some DIP switches were not properly initialized. - Send file and Resend file were not sent properly from VTC upon FTP sending. Ver2.6.2 -------------------------------- Problem Fix - System information was unable to be updated. - FIT resending was not properly performed. - The default setting of wireless LAN was not updated upon updating. - In DIP switch setting, wireless LAN was unable to be initialized. Ver2.6.1 -------------------------------- - From HMI, data of Modbus address (Holding Register) in the range of 0x2000 to 0x4800 can be acquired. Problem fix: - The system shuts down when using TP link driver (8188eu). -Updating stops when connecting through wireless LAN - Updating stopped while connecting by wireless LAN (wifi_crond.sh operation). - In the setting item (data format) of PLC setting, 32-bit signed was described as 32-bit unsigned on the English display. - String calculation control of VTC worked differently from the previous version. Fixed: Insert an empty string into STAG when number of characters to extract is 0 or out of range. Ver2.6.0 -------------------------------- - PLC Link type was added. Support MELSEQ iQ-R series(normal,duplex) Mitsubishi_iQ-R.plc Mitsubishi_iQR_3E_ascii.lin Mitsubishi_iQR_3E_bin.lin Mitsubishi_iQR_4C_ascii.lin Mitsubishi_iQR_Con_3E_ascii.lin Mitsubishi_iQR_Con_3E_bin.lin Mitsubishi_iQR_Con_4C_ascii.lin Support TOYOPUC PC10 series PC10G-CPUE.plc PC10G-CPUS.plc TY_PC10E.lin TY_PC10S.lin - Data format was added in PLC device settings. Unsigned 16bit data Signed 16bit data Unsigned 32bit data(BE) Signed 32bit data(BE) Unsigned 32bit data(LE) Signed 32bit data(LE) - Task function was added. FTP Send FTP Receive PLC Trigger - Data format settings in Input Modbus and Output Modbus were added. Unsigned data(16bit) Signed data(16bit) Unsigned data(32bit) Signed data(32bit) For 32bit data, word order can be selected from little-endian or big-endian. - FTP server setting page was added. - Modbus address to store PLC data was extended. Holding Register 0x2000-0x2400 to 0x2000-0x4800 Problem fix: - "Transfer Info" in the system information register(Modbus0x5024)is displayed incorrectly. - CONPROSYS stops working when operating with a wireless LAN. - Wireless LAN cannot be reconnected to AP automatically. - Tag 10-15 in the debug dialog of task is displayed incorrectly. Ver2.5.1 -------------------------------- - The page of User/Password setting was changed. - The group which has the intermediate privilege between the root and the other was added. (The group name: User) - The group names were redefined due to an addition of the user group. Root- Admin User- User (intermediate group) Other- Guest Problem fix: - The second time Open fails when the VTC commands the COM port to be opened or closed. - FANUC CNC data cannot be set in PrintOutput in the specified order. Ver2.5.0 -------------------------------- - The function was added in OPC UA containing model(CPS-MG341G-ADSC1-930,CPS-MG341-ADSC1-931). - STAG was added in UA tree. - Support MTConnect (CPS-MG341G-ADSC1-930,CPS-MG341-ADSC1-931) - MTConnect was added in the menu of configuration. - MTConnect was added in the service setting of configuration page. - Change the file at the initial setting of the monitoring screen. - Changed that wireless LAN can be used even when booting with DIP SW 1 - 2 is ON. - Problem fix: Status information of digital input power was not set properly. Ver2.4.1 -------------------------------- Problem fix: - The higher 8 bits of the received data have been disappered in binary communication by Mitsubishi PLC. Ver2.4.0 -------------------------------- - The new model CPS-MG341G-ADSC1-930 was added. Ver2.3.2 -------------------------------- Problem fix: When connecting to the network via USB wireless LAN, timeout will be performed if IP address is not assigned from dhcp server within a specified time. Problem fix: Even SW1 No. 2 is on, USB wireless LAN operates by user setting. - A box becomes inactive if Search is selected in SSID of the wireless LAN set ting.The scan button and the list become inactive if Manual is selected. - LAN A and LAN B can be set on OPC UA setting page. - TCP port (1~65535) can be set on OPC UA setting page. - The notation of OPC-UA changed to OPC UA. Ver2.3.1 -------------------------------- Problem fix: Task ends when accessing DO from the task. Ver2.3.0 -------------------------------- - Administrator setting function was added. Separate into two groups of Administrator (root) and General users (other) - The additional function in Login password setting was added. A user can choose whether to enter User and Password is necessary at log-in. (User and Password are always required in the Administrator page) - HMI Editor Version upgrading ver2.12.1 - Task Editor Version upgrading ver1.11 - TAG00 - 99 were added in the OPC-UA tree. - Azure data sending function became available. - File compression function in Auto backup folder was added. Backup files are compressed at 3:59 am once a day. (excludes from 0:00 to 3:59) - Support communication with FANUC CNC (Model 931 exclusively) Serial communication port setting in the device setting was added on the Web configuration page. Communication data was added in OPC-UA data. - Start-up process of the DIP switch changed. When DIP-SW1 is 2:ON 3:OFF, IP starts with default state. (login user should not be default state) - TELEC number display was added in the system information of 3G model. Ver2.2.0 -------------------------------- -CPS-MG341-ADSC1-931 support OPC-UA function within model -Updated Kernel -Enhanced Modbus Slave function System information was added to 0x5000 and later addresses of the input register. -USB Wifi support -Updated PLC communication -Mitsubishi Q series binary communication support -Mitsubishi FX3G, FX3U definition added -Mitsubishi iQ-F (FX5U), iQ-R(RxxCPU) definition added -Updated VTC (ver1.10) Details are listed on the manual online http://data.conprosys.com/help/task/V1/jp/ -Updated HMI (ver2.12.0) Details are listed on the manual online http://data.conprosys.com/help/hmi/V1/jp/ Ver2.1.0 -------------------------------- -Mail sending function was added. Ver2.0.4 -------------------------------- Apply CDS2 -Added "CDS2 format" and "Cloudkey" for Data transfer setting. When CDS2 was set as "Enable", a format of csv file sent by data transfer service was changed as follows: -Cloudkey -Date -Time -Millisecond After the above, measured data were listed. -Added "Datetime(CDS)" for VTC log control. -Added a name "Second" for a file that was sent to Cloud server from VTC. File name: YYYYMMDDhhmmss_filexx.csv Apply Proxy -Added Proxy setting for the network setting Ver2.0.2 -------------------------------- Problem fix: -Device setting did not accept additions if Link setting, CPU setting, and Device setting were saved with the same names. -Some programs exited unexpectedly when accessing from the task beyond the range of Modbus address. -Address specification of Modbus input control in VTC did not work well. Ver2.0.1 -------------------------------- Problem fix: -Data transfer to the cloud server did not work properly when operating for a long time with the screen of HMI, VTC displayed. -When a communication error occurs continuously on the MODBUS RTU, the system did not operate properly. Ver2.0.0 -------------------------------- -Implement new monitoring and task Program fixed: -The pop-up for the details of PLC communication setting was not displayed. -Modified transfer process upon sending data to cloud -Modified time setting screen. Ver1.0.6f -------------------------------- -Modified Re-try at the time of communication error with PLC -Changed to PLC data-stop from PLC data-save before synchronization. -Changed the time-out value of Ethernet communication -Fixed the display errors of device list. -Modified the process upon re-transferring data to cloud. -Fixed unsatisfactory communication with OMRON C series. Ver1.0.0 -------------------------------- Released the first edition.