===================================================================== = CPS-MG341 Series Firmware Upgrade = = CPS-MG341 Series firmware Ver2.6.4 = = CONTEC Co.,Ltd. = ===================================================================== Ÿ Table of Contents ======= Introduction Before upgrading Version upgrading procedure Version upgrading history Ÿ Introduction =========== Thank you for your continued patronage of CONTEC products. This describes the additional information of CPS-MG341 series firmware upgrade. For how to use the product, please visit our website and see the system setup guide. (http://www.contec.com) Ÿ Firmware upgrading precaution =========== *Do not downgrade the firmware. *The required time for upgrading CPS-MG341-ADSC1-931: about 15 minutes other models: about 40 minutes *********************************************************************** * Do not turn off the power when LED ST1 and ST2 are on. * * Doing so may break the data and device will be unable to boot. * *********************************************************************** * The former task program (1.0.6f or earlier) will convert and run in the .2.0.0 and later version. However, the screen that was created in the former monitoring (1.0.6f or earlier) cannot be used. The screen needs to be created again with new tools. Ÿ Before upgrading =========== Have the followings ready - Product (CPS-MG341 series) - Host computer - LAN cable - Firmware upgrade file Ÿ Version upgrading procedure =========== 1.Turn on the power of the CPS-MG341 product. 2.Connect the product to a host computer with a LAN cable. 3.Access the product via web browser from the computer . If the CPS-MG341 still has the default setting, set the host computer on the same network (e.g.:10.1.1.102) and enter "http://10.1.1.101 " in URL. If you are uncertain of your IP address, the default settings (10.1.1.101) can be restored temporarily by turning on the power with SW1-2 switch on. 4.Log in the product. You will be asked to enter a user name and a password. Enter them and click "OK" button. If you are uncertain of the user name and/or password, the default settings (User nameFmc341, PasswordFmc341) can be restored temporarily by turning on the power with SW1-2 switch on. 5.Follow the instruction below to go to "Firmware version up" menu. In the "Status nemu", click "Maintenace menu", and then "Firmware version up"in the Backup group. 6.Upload the firmware upgrade file. Click "Browse" button. Specifiy the file in the host computer to upload. Click "upload" button. *If the firmware upgrade file is compressed (extension:zip), decompress it before uploadingiextension:bin). 7.Upgrading will start and the product will be rebooted. LED display changes as described below. Upgrading ‡@PWR on, ST1 flashing (slow), ST2 off ‡APWR on, ST1, ST2 flashing (fast) ‡BPWR on, ST1, ST2 off ‡CPWR on, ST1, ST2 flashing (slow) Rebooting ‡DPWR, ST1, ST2 on ‡EPWR on, ST1, ST2 off ‡FPWR on, ST1 flashing (slow), ST2 off 8.After rebooting completes, check the version. Access the product via web browser again. From "Maintenance menu", click "System information" under the group of System. Ÿ Version upgrading history =========== Ver2.6.4 -------------------------------- Problem Fix - When writing with F•eIT protocol into a device, it shoultid response by 0x40 if the resource of queue was insufficient. Ver2.6.3 -------------------------------- Problem Fix - After the device is activated, there is a problem with LAN A (eth0) about the network connection. ModelFCPS-MG341G-ADSC1-111 Ver2.6.2 -------------------------------- Problem Fix - System information was unable to be updated. - FIT resending was not properly performed. - The default setting of wireless LAN was not updated upon updating. - In DIP switch setting, wireless LAN was unable to be initialized. Ver2.6.1 -------------------------------- - From HMI, data of Modbus address (Holding Register) in the range of 0x2000 to 0x4800 can be acquired. Problem fix: - The system shuts down when using TP link driver (8188eu). -Updating stops when connecting through wireless LAN - Updating stopped while connecting by wireless LAN (wifi_crond.sh operation). - In the setting item (data format) of PLC setting, 32-bit signed was described as 32-bit unsigned on the English display. - String calculation control of VTC worked differently from the previous version. Fixed: Insert an empty string into STAG when number of characters to extract is 0 or out of range. Ver2.6.0 -------------------------------- - PLC Link type was added. Support MELSEQ iQ-R series(normal,duplex) Mitsubishi_iQ-R.plc Mitsubishi_iQR_3E_ascii.lin Mitsubishi_iQR_3E_bin.lin Mitsubishi_iQR_4C_ascii.lin Mitsubishi_iQR_Con_3E_ascii.lin Mitsubishi_iQR_Con_3E_bin.lin Mitsubishi_iQR_Con_4C_ascii.lin Support TOYOPUC PC10 series PC10G-CPUE.plc PC10G-CPUS.plc TY_PC10E.lin TY_PC10S.lin - Data format was added in PLC device settings. Unsigned 16bit data Signed 16bit data Unsigned 32bit data(BE) Signed 32bit data(BE) Unsigned 32bit data(LE) Signed 32bit data(LE) - Task function was added. FTP Send FTP Receive PLC Trigger - Data format settings in Input Modbus and Output Modbus were added. Unsigned data(16bit) Signed data(16bit) Unsigned data(32bit) Signed data(32bit) For 32bit data, word order can be selected from little-endian or big-endian. - FTP server setting page was added. - Modbus address to store PLC data was extended. Holding Register 0x2000-0x2400 to 0x2000-0x4800 Problem fix: - "Transfer Info" in the system information register(Modbus0x5024)is displayed incorrectly. - CONPROSYS stops working when operating with a wireless LAN. - Wireless LAN cannot be reconnected to AP automatically. - Tag 10-15 in the debug dialog of task is displayed incorrectly. Ver2.5.1 -------------------------------- - The page of User/Password setting was changed. - The group which has the intermediate privilege between the root and the other was added. (The group name: User) - The group names were redefined due to an addition of the user group. Root- Admin User- User (intermediate group) Other- Guest Problem fix: - The second time Open fails when the VTC commands the COM port to be opened or closed. - FANUC CNC data cannot be set in PrintOutput in the specified order. Ver2.5.0 -------------------------------- - The function was added in OPC UA containing model(CPS-MG341G-ADSC1-930,CPS-MG341-ADSC1-931). - STAG was added in UA tree. - Support MTConnect (CPS-MG341G-ADSC1-930,CPS-MG341-ADSC1-931j - MTConnect was added in the menu of configuration. - MTConnect was added in the service setting of configuration page. - Change the file at the initial setting of the monitoring screen. - Changed that wireless LAN can be used even when booting with DIP SW 1 - 2 is ON. - Problem fix: Status information of digital input power was not set properly. Ver2.4.1 -------------------------------- Problem fix: - The higher 8 bits of the received data have been disappered in binary communication by Mitsubishi PLC. Ver2.4.0 -------------------------------- - The new model CPS-MG341G-ADSC1-930 was added. Ver2.3.2 -------------------------------- Problem fix: When connecting to the network via USB wireless LAN, timeout will be performed if IP address is not assigned from dhcp server within a specified time. Problem fix: Even SW1 No. 2 is on, USB wireless LAN operates by user setting. - A box becomes inactive if Search is selected in SSID of the wireless LAN set ting.The scan button and the list become inactive if Manual is selected. - LAN A and LAN B can be set on OPC UA setting page. - TCP port (1~65535) can be set on OPC UA setting page. - The notation of OPC-UA changed to OPC UA. Ver2.3.1 -------------------------------- Problem fix: Task ends when accessing DO from the task. Ver2.3.0 -------------------------------- - Administrator setting function was added. Separate into two groups of Administrator (root) and General users (other) - The additional function in Login password setting was added. A user can choose whether to enter User and Password is necessary at log-in. (User and Password are always required in the Administrator page) - HMI Editor Version upgrading ver2.12.1 - Task Editor Version upgrading ver1.11 - TAG00 - 99 were added in the OPC-UA tree. - Azure data sending function became available. - File compression function in Auto backup folder was added. Backup files are compressed at 3:59 am once a day. (excludes from 0:00 to 3:59) - Support communication with FANUC CNC (Model 931 exclusively) Serial communication port setting in the device setting was added on the Web configuration page. Communication data was added in OPC-UA data. - Start-up process of the DIP switch changed. When DIP-SW1 is 2:ON 3:OFF, IP starts with default state. (login user should not be default state) - TELEC number display was added in the system information of 3G model. Ver2.2.0 -------------------------------- -CPS-MG341-ADSC1-931 support OPC-UA function within model -Updated Kernel -Enhanced Modbus Slave function System information was added to 0x5000 and later addresses of the input register. -USB Wifi support -Updated PLC communication -Mitsubishi Q series binary communication support -Mitsubishi FX3G, FX‚RU definition added -Mitsubishi iQ-F (FX5U), iQ-R(RxxCPU) definition added -Updated VTC (ver1.10) Details are listed on the manual online http://data.conprosys.com/help/task/V1/jp/ -Updated HMI (ver2.12.0) Details are listed on the manual online http://data.conprosys.com/help/hmi/V1/jp/ Ver2.1.0 -------------------------------- -Mail sending function was added. Ver2.0.4 -------------------------------- Apply CDS2 -Added "CDS2 format" and "Cloudkey" for Data transfer setting. When CDS2 was set as "Enable", a format of csv file sent by data transfer service was changed as follows: -Cloudkey -Date -Time -Millisecond After the above, measured data were listed. -Added "Datetime(CDS)" for VTC log control. -Added a name "Second" for a file that was sent to Cloud server from VTC. File name: YYYYMMDDhhmmss_filexx.csv Apply Proxy -Added Proxy setting for the network setting Ver2.0.2 -------------------------------- Problem fix: -Device setting did not accept additions if Link setting, CPU setting, and Device setting were saved with the same names. -Some programs exited unexpectedly when accessing from the task beyond the range of Modbus address. -Address specification of Modbus input control in VTC did not work well. Ver2.0.1 -------------------------------- Problem fix: -Data transfer to the cloud server did not work properly when operating for a long time with the screen of HMI, VTC displayed. -When a communication error occurs continuously on the MODBUS RTU, the system did not operate properly. Ver2.0.0 -------------------------------- -Implement new monitoring and task Program fixed: -The pop-up for the details of PLC communication setting was not displayed. -Modified transfer process upon sending data to cloud -Modified time setting screen. Ver1.0.6f -------------------------------- -Modified Re-try at the time of communication error with PLC -Changed to PLC data-stop from PLC data-save before synchronization. -Changed the time-out value of Ethernet communication -Fixed the display errors of device list. -Modified the process upon re-transferring data to cloud. -Fixed unsatisfactory communication with OMRON C series. Ver1.0.0 -------------------------------- Released the first edition.