拥有丰富的接口和产品线 M2M控制器系列

M2M控制器有两种类型:集成了控制器和I/O接口功能的“精巧一体型”,以及可以在控制器模块上加装I/O接口模块的“堆栈组合型”。 根据安装位置,接线方法和I/O信号数量的不同,用户可以灵活配置。

固件版本升级历史

M2M控制器精巧一体型 CPS-MC341系列

支持产品型号

Ver3.9.0

Functional Improvement Security -WEB server function update.
  WEB server certificate (self-signed), updated trusted root CA certificate bundle.
  Added WEB server certificate (self-signed) issuing function.
  Added function for users to upload any trusted root certificate.
  WAdded setting items for communication methods allowed by the web server.: HTTP, HTTPS, HTTP/HTTPS (default)
-WEB server reinforcement.
  Countermeasures against overflow.
  Countermeasures against denial of service.

Ver3.8.2

New Function Communication The support for the FacilityView function started.
SD card write-protect function enabled.
The support for the OPC UA client function of Node-Red started.

Ver3.8.1

New Function Communication Support for requesting DHCP clients with broadcast flag ON/OFF.
Management Added "Wireless LAN Alive Monitoring" item to the Wireless LAN Settings screen.

Ver3.8.0

Functional
Improvement
Security Added the following vulnerability countermeasures.
1. OS Command Injection Vulnerability
  In the following page, the entered value is not properly validated, which makes it possible to execute OS commands.
 [Network] maintenance page, [Mail] setting page, [Static Routing] setting page, [Port Forwarding] setting page, [IP Filter] setting page
2. Firmware tampering vulnerability
 Firmware structure can be analyzed due to insufficient cryptographic strength of firmware update files.
3. Vulnerability to inadequate access restrictions
 Network maintenance page originally accessible only with administrator privileges can be accessed with normal privileges.

Ver3.7.6

Functional
Improvement
Management Added protocol setting to port forwarding function.

Ver3.7.5

New Function Communication The functions “Forced Reboot” and “Repair SD and Reboot” were added.
The support for the router function started.
DHCP server, static routing, port forwarding, and IP filter functions were added.
Functional
Improvement
MQTT Changed the number of TOPICs for MQTT publish/subscribe to a maximum of 16.
Communication Added "2: SD card error" and "3: write error" for "SD Recognition" in Modbus status.

Ver3.7.4

New Function NTP Rebooting function for NTP time synchronization service was added.
Functional
Improvement
Communication Changed the method for transmitting blank data to Azure.
Management For the "Auto Backup Folder", when there is no free space on the SD card when creating a new compressed file (YYYYMMDD.tgz), added the process of deleting the oldest compressed file to free up space.

Ver3.7.3

New Function Expansion SDK Add custom type [file].
Communication Added the communication monitoring interval to the 920Mhz configuration screen.
Functional
improvement
Management The LED control processing for shutdown by the MCS341 series power switch is integrated with the processing by the MC/MG341 series shutdown switch.

Ver3.7.2

Functional
improvement
Communication Changed the method for transmitting Japanese data to Azure.
Added a setting to enter the PIN code if the SIM is locked.(CPS-MC341G-ADSC1-111, CPS-MC341G-ADSC1-110)
Added AT command history on the log page.
Management Added a function to restart the device when kernel panic occur.

Ver3.7.1

Functional
improvement
Communication Added the function to reassign the IP address when the IP address of the wired LAN (eth0) is lost.
Management Changed the restoring function to restore the specified or all items.
Expansion SDK The device file that can be used in the expansion SDK custom program was added.

Ver3.7.0

New Function Management The industrial value conversion function for analog input values was added. (the CPS-MC341-ADSC1 Series, CPS-MC341-A1)

Ver3.6.1

New Function Communication SMS function was added to the product 3G global model(CPS-MC341G-ADSC1-110).
Functional
improvement
Management SD card was added as a destination to download the backup file to.
The restoring function was changed to restore the specified items.
Files are able to be sent and received to and from multiple FTP servers.
The prohibited character "." to be used in the middle of a folder name was changed to a permitted character.
The number of characters for a password was increased. (30 to 64 alphanumeric characters) in the [Mail] setting page.
On the [Time] setting page, the function was changed to write the time in temporary storage space and RTC by clicking the “Update” button.
Communication The settings of the "Server Connection Timeout" and the "Data Transfer Timeout" were added in the [Data Transfer] function and the[FTP Put] function.
MQTT The number of characters for a client ID was increased. (23 to 256 alphanumeric characters) in the [MQTT Connection] page.

Ver3.6

New Function Management The setting of NTP synchronization time became available.
Modbus The support for the single holding register writing (function code : 0x06) started. AO module (0x0000-) (Modbus Slave function).
Modbus area web monitoring function/writing function were added.
Extension SDK The support was added for the extension SDK USB serial device to be controlled by custom program.
Functional improvement Communication For FTP function, made the folder hierarchy settable from VTC.
MQTT The number of MQTT publish/subscribe data were increased up to 3000 for each cloud key.
The support for CSV import/export for the data settings in MQTT publish/subscribe were added.
Enable and disable functions for each data in MQTT publish/subscribe were added.
Two types for the publishing options in MQTT publish setting were added.
Changed for cloud key to be specified when STAG is set for payload in MQTT subscribe setting.
Rebooting function for MQTT service was added.

Ver3.5

New Function Communication QTT Client function was added.
Specifying and function for destination service were added in data transfer settings.
New support for wireless LAN USB was available.

Ver3.4

New Function OPC UA The Listen port is able to be edited. The Response Address is able to be edited.
Functional improvement Management Displaying a warning popup was added when the pre-set user password is remained as the default settings.
Communication Supports restart function of Data Transfer, PLC, 3G, 920MHz and OPC UA.

Ver3.3

New Function VTC Added Expansion SDK. It is now possible to add a user program developed with the Linux SDK and execute it from VTC.

Ver3.2

New Function Management Increased the user management function. Limitations on the functions for a general user are changed.(Administrator only)
HMI The operation status graph is added in HMI graph item.
Functional improvement VTC Added TAG information import / export function.
The number of saved task pages is increased to 20 pages.
The variables numbers of TAGs and STAGs are increased up to 500 respectively.
The Comment setting, Display, and Monitoring functions are added.
Communication Wireless LAN encryption supported * When using a compatible USB wireless LAN dongle.

Ver3.1

New Function Management Added the function to switch the display language according to the language setting of the browser.

Ver3.0

New Function VTC Calculating control was added.
For system information control, the contents such as serial number were added.
Functional improvement Management Upgrade WEB setting screen.
Communication 920Mhz sampling data transfer and reception function was added. (To support CPS-MC341Q-ADSC1-111 controller) (Japan Only)
Supports communication with the wireless I/O module of 920Mhz model. (DIO-0404LY-WQ, AI-1004LY-WQ) (Japan Only)
I/O Added digital filter setting function for the CPS-MC341x-ADSC1 controllers.

Ver2.5

New Function Communication FTP client function was added.
Functional improvement Management Added an intermediate authority group, User (user) between the group of Root (Admin) and Other (guest).
VTC "String treats as" property was added in each control of Calc String and Split String.
"Get data size" was added in Action property of Str2Num control.
FTP(Put) and FTP(Get) controls were added.
FANUC CNC input control was added.

Ver2.4

New Function Communication Supports MTConnect conmmunication (CPS-MC341-ADSC1-931).
Functional improvement Communication STAG was added in OPC UA tree (CPS-MC341-ADSC1-931).

Ver2.3

New Function Communication Azure data sending function became available.
Mail sending function was added.
I/OSupports USB WiFi of TP-LINK.
Functional improvement Management Kernel updated.
Administrator setting function was added. Separate into two groups of Administrator (root) and General users (other).
File compression function in Auto backup folder was added.
Added a boot mode that initializes only the IP address and boots.
Communication TAG00 - 99 were added in the OPC-UA tree. *CPS-MC341-ADSC1-931
Enhanced Modbus Slave function: System information was added to 0x5000 and later addresses of the input register
HMI Check the ROM space when saving HMI settings.

Ver2.2

Functional improvement Management Added Proxy setting for the network setting.
Communication Added "CDS2 format" and "Cloudkey" for CDS2 Data transfer setting.
VTC Added "Datetime(CDS)" for VTC log control.
Added a name "Second" for a file that was sent to Cloud server from VTC.

Ver2.1

New Function Communication Supported communication with FANUC CNC.

Ver2.0

New Function VTC Greatly improved the task script function CONPROSYS VTC
HMI Substantially improved monitoring function CONPROSYS HMI
Management Applied Chinese version

Ver1.8

New Function Management Supports CPS-MC341G-ADSC1-110

Ver1.7

New Function VTC Task programming functions were added: Cloud server transmission / File generation / File read / File operation / Log file output / SD card backup.
Functional improvement Management Network continuity check function was added.
Time synchronization setting: Write date and time into hardware manually.
Added file browsing and deleting functions.

Ver1.6

New Function Management Supports CPS-MC341-DS2-111 controller.
Functional improvement Management Optimize start-up process.

Ver1.5

New Function Management Supports CPS-MC341Q-ADSC1-111 controller.(Japan Only)

Ver1.4

New function Management Supports CPS-MC341-A1-111 controller.

Ver1.3

New Function Management Supports CPS-MC341G-ADSC1-111 controller.

Ver1.2

New Function Management Supports CPS-MC341-DS1-111 controller.

Ver1.1

New Function Management Kernel updated
Supports CPS-MC341-ADSC2-111 controller.
Functional improvement Management Start sending data to the server upon completeion of time synchronization.

Ver1.0

New Function Management Released the first edition.
Supports CPS-MC341-ADSC1-111 controller.

M2M控制器堆栈组合型 CPS-MCS341系列

支持产品型号

Ver3.10.0

Functional Improvement Security -WEB server function update.
  WEB server certificate (self-signed), updated trusted root CA certificate bundle.
  Added WEB server certificate (self-signed) issuing function.
  Added function for users to upload any trusted root certificate.
  WAdded setting items for communication methods allowed by the web server.: HTTP, HTTPS, HTTP/HTTPS (default)
-WEB server reinforcement.
  Countermeasures against overflow.
  Countermeasures against denial of service.

Ver3.9.4

New Function Communication Displayed LTE module version of the model below.
model: CPS-MCS341G5-DS1-130

Ver3.9.2

New Function Communication The support for the FacilityView function started.
SD card write-protect function enabled.
The support for the OPC UA client function of Node-Red started.

Ver3.9.1

New Function Communication Support for requesting DHCP clients with broadcast flag ON/OFF.
Management Added "Wireless LAN Alive Monitoring" item to the Wireless LAN Settings screen.
The function to set startup data was added to the TAG settings of the tag edit function.
Product concerned : CPS-MCS341G5-DS1-130

Ver3.9.0

Functional
Improvement
Security Added the following vulnerability countermeasures.
1. OS Command Injection Vulnerability
  In the following page, the entered value is not properly validated, which makes it possible to execute OS commands.
 [Network] maintenance page, [Mail] setting page, [Static Routing] setting page, [Port Forwarding] setting page, [IP Filter] setting page
2. Firmware tampering vulnerability
 Firmware structure can be analyzed due to insufficient cryptographic strength of firmware update files.
3. Vulnerability to inadequate access restrictions
 Network maintenance page originally accessible only with administrator privileges can be accessed with normal privileges.

Ver3.8.8

Functional
Improvement
Management Added protocol setting to port forwarding function.

Ver3.8.7

New Function Communication The functions “Forced Reboot” and “Repair SD and Reboot” were added.
The support for the router function started.
DHCP server, static routing, port forwarding, and IP filter functions were added.
Functional
Improvement
MQTT Changed the number of TOPICs for MQTT publish/subscribe to a maximum of 16.
Communication Added "2: SD card error" and "3: write error" for "SD Recognition" in Modbus status.
Added "1 min" setting item to Cycle of LTE Alive Monitoring on the LTE setting.

Ver3.8.5

New Function NTP Rebooting function for NTP time synchronization service was added.
Functional
Improvement
Communication Changed the method for transmitting blank data to Azure.
Management For the "Auto Backup Folder", when there is no free space on the SD card when creating a new compressed file (YYYYMMDD.tgz), added the process of deleting the oldest compressed file to free up space.

Ver3.8.4

New Function Communication Added the communication monitoring interval to the 920Mhz configuration screen.

Ver3.8.3

New Function Expansion SDK Added Expansion SDK
Supports control of serial devices of stack model expansion I/O modules from custom program.
Add custom type [file].
Functional
improvement
Management Added a function to restart the device when kernel panic occur.
The LED control processing for shutdown by the MCS341 series power switch is integrated with the processing by the MC/MG341 series shutdown switch.

Ver3.8.2

New Function Management Added a setting to enter the PIN code if the SIM is locked. (CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130)
Added AT command history on the log page. (CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130)
Functional
improvement
Communication Changed the method for transmitting Japanese data to Azure.

Ver3.8.1

Functional
improvement
Communication Added the function to reassign the IP address when the IP address of the wired LAN (eth0) is lost.
Management Changed the restoring function to restore the specified or all items.
Expansion SDK The device file that can be used in the expansion SDK custom program was added.

Ver3.8.0

New Function Management The industrial value conversion function for analog input values was added (the CPS-AI-1608LI and CPS-AI-1608ALI modules).
Communication The support for the LTE and SMS functions started (the CPS-MCS341G5-DS1-130 model).

Ver3.7.1

New Function Communication SMS function was added to the product 3G model(CPS-MCS341G-DS1-130).
Functional
improvement
Management SD card was added as a destination to download the backup file to.
The restoring function was changed to restore the specified items.
Files are able to be sent and received to and from multiple FTP servers.
The prohibited character "." to be used in the middle of a folder name was changed to a permitted character.
The number of characters for a password was increased. (30 to 64 alphanumeric characters) in the [Mail] setting page.
On the [Time] setting page, the function was changed to write the time in temporary storage space and RTC by clicking the “Update” button.
Communication The settings of the "Server Connection Timeout" and the "Data Transfer Timeout" were added in the [Data Transfer] function and the[FTP Put] function.
MQTT The number of characters for a client ID was increased. (23 to 256 alphanumeric characters) in the [MQTT Connection] page.

Ver3.7

New Function Management The setting of NTP synchronization time became available.
Modbus The support for the single holding register writing (function code : 0x06) started. AO module (0x0000-) (Modbus Slave function).
Modbus area web monitoring function/writing function were added.
Extension SDK The support was added for the extension SDK USB serial device to be controlled by custom program.
Functional improvement Communication For FTP function, made the folder hierarchy settable from VTC.
MQTT The number of MQTT publish/subscribe data were increased up to 3000 for each cloud key.
The support for CSV import/export for the data settings in MQTT publish/subscribe were added.
Enable and disable functions for each data in MQTT publish/subscribe were added.
Two types for the publishing options in MQTT publish setting were added.
Changed for cloud key to be specified when STAG is set for payload in MQTT subscribe setting.
Rebooting function for MQTT service was added.

Ver3.6

New Function Communication MQTT Client function was added.
Specifying and function for destination service were added in data transfer settings.
New support for wireless LAN USB was available.

Ver3.5

New Function OPC UA The Listen port is able to be edited. The Response Address is able to be edited.
Functional improvement Management Displaying a warning popup was added when the pre-set user password is remained as the default settings.
Communication Supports restart function of Data Transfer, PLC, 3G, 920MHz and OPC UA.

Ver3.4

New Function VTC Added Expansion SDK. It is now possible to add a user program developed with the Linux SDK and execute it from VTC.

Ver3.3

New Function Management Increased the user management function. Limitations on the functions for a general user are changed.(Administrator only)
Communication CPS-MCS341G-DS1-130 supports OPC UA/MTConnect.
HMI The operation status graph is added in HMI graph item.
Functional improvement VTC Added TAG information import / export function.
The number of saved task pages is increased to 20 pages.
The variables numbers of TAGs and STAGs are increased up to 500 respectively.
The Comment setting, Display, and Monitoring functions are added.
Communication Wireless LAN encryption supported * When using a compatible USB wireless LAN dongle.

Ver3.2

New Function I/O Supports new I/O Module: CPS-MM-LC (Leakage Current Monitoring Module)
HMI The tag (I0/I0r/Va/R), which get the data from the CPS-MM-LC module, was added to HMI.

Ver3.0

New Function Management Added the function to switch the display language according to the language setting of the browser.
VTC Calculating control was added.
For system information control, the contents such as serial number were added.
Functional improvement Management Upgrade WEB setting screen.
Communication 920Mhz sampling data transfer and reception function was added. (To support CPS-MC341Q-ADSC1-111 controller)(Japan Only)
Supports communication with the wireless I/O module of 920Mhz model (DIO-0404LY-WQ,AI-1004LY-WQ).(Japan Only)

Ver2.8

New Function Communication FTP client function was added.
Functional improvement Management Added an intermediate authority group, User (user) between the group of Root (Admin) and Other (guest).
VTC "String treats as" property was added in each control of Calc String and Split String.
"Get data size" was added in Action property of Str2Num control.
FTP(Put) and FTP(Get) controls were added.
FANUC CNC input control was added.

Ver2.7

New Function Communication Supports MTConnect(CPS-MCS341-DS1-131,CPS-MCS341Q-DS1-131.
Functional improvement Communication The function was added in OPC UA containing model(CPS-MCS341-DS1-131,CPS-MCS341Q-DS1-131). STAG was added in UA tree.

Ver2.6

New Function Communication Supports communication with FANUC CNC.
Azure data sending function became available.
Mail sending function was added.
I/O Supports USB WiFi of TP-LINK.
Functional improvement Management Updated Kernel
Administrator setting function was added. Separate into two groups of Administrator (root) and General users (other).
File compression function in Auto backup folder was added.
Added a boot mode that initializes only the IP address and boots.
Communication TAG00 - 99 were added in the OPC-UA tree. *CPS-MC341-ADSC1-931
Enhanced Modbus Slave function: System information was added to 0x5000 and later addresses of the input register.
HMI Check the ROM space when saving HMI settings.

Ver2.4

Functional improvement Management Added Proxy setting for the network setting.
Communication Added "CDS2 format" and "Cloudkey" for CDS2 Data transfer setting.
VTC Added "Datetime(CDS)" for VTC log control.
Added a name "Second" for a file that was sent to Cloud server from VTC.

Ver2.3

New Function Management Supports CPS-MCS341Q-DS1-130 (Japan Only)

Ver2.2

New Function I/O I/O module applied ( CPS-DI-16L , CPS-DI-16RL , CPS-DO-16L , CPS-DO-16RL )

Ver2.1

New Function Management Supports CPS-MCS341G-DS1-130.

Ver2.0

New Function Management Supports CPS-MC341-ADSC2-111.
I/O I/O module applied ( CPS-AI-1608ALI , CPS-AO-1604VLI , CPS-DIO-0808RL , CPS-RRY-4PCC , CPS-CNT3202I )
VTC Greatly improved the task script function CONPROSYS VTC
HMI Substantially improved monitoring function CONPROSYS HMI
Functional improvement Management Start sending data to the server upon completeion of time synchronization.

Ver1.0.1

New Function I/O I/O module applied ( CPS-AI-1608LI , CPS-AO-1604LI , CPS-SSI-4P )
VTC Task programming functions were added: Cloud server transmission / File generation / File read / File operation / Log file output / SD card backup.
Functional improvement Management Network continuity check function was added.
Time synchronization setting: Write date and time into hardware manually.
Added file browsing and deleting functions.

Ver1.0

New Function Management Released the first edition.
Supports CPS-MCS341-DS1-111
I/O I/O module applied ( CPS-DIO-0808L , CPS-DIO-0808BL , CPS-COM-1PC , CPS-COM-2PC , CPS-COM-1PD , CPS-COM-2PD )

研讨会资料

CONPROSYS系列的 研讨会资料Ver. 3.20 (英语)

免费下载

资料请求, 报价, 购买前的咨询

联系我们

  • 研讨会资料 免费下载

    CONPROSYS系列的 研讨会资料Ver. 3.20 (英语)

    免费下载

  • 资料请求, 报价, 购买前的咨询

    联系我们

页面顶部

To PageTop