M2M Controller Series Integrated Type |
Ver3.7.1 -> Ver3.7.2
--------------------------------
- Changed the method for transmitting Japanese data to Azure.
- The function was added to the product 3G model(CPS-MC341G-ADSC1-111, CPS-MC341G-ADSC1-110).
Added a setting to enter the PIN code if the SIM is locked.
Added AT command history on the log page.
- Added a function to restart the device when kernel panic occur.
Problem Fix
- Fix CHS function below
"Cloudkey" can't be registered when a new tag is added to it.
- Parentheses, "(" and ")", can't be used for password on 3G setting.
- Fixed startup process of CPS-MC341G-ADSC1-110.
- Fix the process of restart 3G module.
model: CPS-MC341G-ADSC1-111
- VTC was updated (ver1.79 to ver1.80).
Baudrate:460800 bps can be selected from serial setting of "Link setting". For details, refer to “Online Help”.
| Download |
M2M Controller Series Configurable Type |
Ver3.8.2 -> Ver3.8.3
--------------------------------
- Added a function to restart the device when kernel panic occur.
- The LED control processing for shutdown by the MCS341 series power switch is integrated with the processing by the MC/MG341 series shutdown switch.
- Added Expansion SDK
Supports control of serial devices of stack model expansion I/O modules from custom program.
Add custom type [file].
Problem Fix
- Fix the process of restart 3G module.
model: CPS-MCS341G-DS1-130
- Fixed display of COM port number when connecting to CPS-MM-LC.
- 920Mhz setting is not reflected in User's Restrictions.
- Expansion SDK was fixed
Cannot remove or edit options of custom programs for startup if they contain the "/" character.
Unable to get local time in custom program.
- VTC stops working when VTC accesses an unregistered 920MHz Child unit.
| Download |
M2M Gateway Series |
Ver3.7.1 -> Ver3.7.2
--------------------------------
- Changed the method for transmitting Japanese data to Azure.
- The function was added to the product 3G model(CPS-MG341G-ADSC1-930) and LTE model(CPS-MG341G5-ADSC1-931).
Added a setting to enter the PIN code if the SIM is locked.
Added AT command history on the log page.
- Added settings for Mitsubishi MELSEC FX Series PLCs.
Communication method : Ethernet
Format : BINARY
- Added a function to restart the device when kernel panic occur.
Problem Fix
- Fix CHS function below
"Cloudkey" can't be registered when a new tag is added to it.
- Parentheses, "(" and ")", can't be used for password on 3G setting.
- Fixed the problem that communication is not performed correctly for multiple channels of bit devices when the PLC communication settings are as follows.
OMRON SYSMAOMRON SYSMAC CS/CJ/CP Series Serial/Ethernet communication.
- Fixed startup process of CPS-MG341G-ADSC1-930.
- OMRON SYSMAC CS/CJ/CP Series serial communication.
Improved processing when requesting a READ
Specifying the station number
- Fix the process of restart 3G module.
model: CPS-MG341G-ADSC1-111
- VTC was updated (ver1.79 to ver1.80).
Baudrate:460800 bps can be selected from serial setting of "Link setting". For details, refer to “Online Help”.
| Download |