Remote I/O System for IoT nano Series

Remote I/O devices for digitizing interspersed local devices.
CONPROSYS nano is easy to use and excellent cost performance, which accelerates digital transformation of industrial systems.

CONPROSYS nano Functionality

Best Value Remote I/O

Remote I/O equipment that does not compromise ease of use and narrowed down to necessary functions. Modular design realizes lean configuration with minimum required I/Os.

I/O module

Programmable with IEC 61131-3 PLC Languages

Coupler Unit Programmable Remote I/O

CODESYS runtime that supports the IEC61131-3 PLC languages has been built-in. It is possible to write a control program developed in a CODESYS development environment into the unit.

CODESYS

Supports Windows PC, Linux PC, or Modbus Device

Coupler Unit Remote I/O

It can be used as a remote I/O device of equipment with Modbus master function such as Windows PC, Linux PC*, and PLC.

Compatible with 35 mm DIN rail Easy to insert and remove an I/O module

Benefits of CONPROSYS nano Series

Flexible Modular Type Remote I/OFlexible Modular type Remote I/O

Highly Efficient Programmable Remote I/OHighly efficient programmable Remote I/O

System Configuration Examples Utilizing CONPROSYS nano Series

PC-based Remote I/O System utilizing Windows PC or Linux PC

Windows / Linux driver software are ready. Remote I/O system can be configured by industrial PC as a master controller.

PC-based Remote I/O System utilizing Windows PC or Linux PC

Simple Remote I/O System using a PLC as the Master Controller

Supports Modbus communication. Remote I/O system can be configured by Modbus supported PLC as a master controller.

IoT Data Collection / Distribution Control System in Cooperation with CONPROSYS Series

CONPROSYS M2M Gateway will make it easier to collect data and upload it to upper network.
The PLC program can be written into the programmable remote I/O unit with CODESYS. While functioning as an autonomous controller, it is a Modbus slave device that responds to the upper controller.

Line Up

Coupler Unit

Remote I/O 4-slot

Model Function Power Supply Dimension Installation Method Operating Temperature
Windows / Linux driver
control
Modbus-TCP slave
12-24VDC 110(W) x 74.8(D) x (95(H)(mm)
(4.33”(W)x2.94”(D)x3.74”(H))
35 mm DIN rail Screw -20 to +60°C
(-4 to +140°F)*1
Windows/Linux driver
Modbus-TCP slave
2xLAN(contains a switch function)
4x I/O Module slots
12-24VDC 110(W) x 74.8(D) x (95(H)(mm)
(4.33”(W)x2.94”(D)x3.74”(H))
35 mm DIN rail Screw -20 to +60°C
(-4 to +140°F)*1

Programmable Remote I/O 4-slot

Model Function Power Supply Dimension Installation Method Operating Temperature
IEC 61131-3 compliant
programming
Modbus-TCP / slave
12-24VDC 110(W) x 74.8(D) x (95(H)(mm)
(4.33”(W)x2.94”(D)x3.74”(H))
35 mm DIN rail Screw -20 to +60°C
(-4 to +140°F)※1
  • *1
    ※ In case the unit is wall mounted by left 90° or right 90°, or placed flatly, the range is -20 to +55°C (-4 to +131°F).

I/O Modules

Digital Input and Output Modules

Model Input Output Power Consumption Connector
8ch
Opto-coupler isolated input
Supports current sink (negative logic) or source (positive logic) output
3.3VDC 50mA(Max.) Screw terminal block
(3.81mm/0.15” pitch 10 pins)
8ch
Opto-coupler isolated input
Supports current sink output (negative logic)
5VDC 110mA(Max.)
3.3VDC 50mA(Max.)
8ch
Opto-coupler isolated open collector output Current sink type (negative logic)
3.3VDC 90mA(Max.)
8ch
Opto-coupler isolated open collector output Current sink type (negative logic)
5VDC 130mA (Max.)
3.3VDC 90mA (Max.)

Analog Input Module

Model Input Format*1 No. of Input Channels Input Voltage*1 Input Current*1*2 Power Consumption Connector
Single-end input
or differential input
8ch (single-end input)
4ch (differential input)
±10V、±5V、
±2.5V、0-10V、
12bit (Bus isolated)
±20mA 12bit、
(Bus isolated)
5VDC 210mA(Max.)
3.3VDC 10mA(Max.)
Screw terminal block
(3.81mm/0.15” pitch 10 pins)
  • *1
    All input channels are assigned for the same input format and input range.
  • *2
    Current input is only for differential input.

Serial Communication Module

Model Transmission Scheme No. of CH/ Isolation Power Consumption Connector
Asynchronous serial
transmission
(Full duplex / Half duplex)
1ch / Bus isolated 5VDC 250mA(Max.)
3.3VDC 20mA(Max.)
Screw terminal block (3.81mm/0.15” pitch 10 pins)

Industrial Switching HUB

100BASE-TX, 8-port Type, Wide Temperature Range

  • Operating temperature from -20 to +60°C
  • Supports 8 ports with 100BASE-TX wiring countermeasure circuit built-in
  • Power supply redundant, power supply reverse
  • Mountable on the 35mm DIN Rail
  • Compact Size (40(W) x 60(D) x 90(H) mm) / (1.57(W) x 2.36(D) x 3.54(H) inch)

100BASE-TX, 5-port Type, Wide Temperature Range

  • Operating temperature from -20 to +60°C
  • Supports 5 ports with 100BASE-TX
  • Power supply redundant, power supply reverse wiring countermeasure circuit built-in
  • Mountable on the 35mm DIN Rail
  • Compact Size (25.2(W) x 94.7(D) x 124.8(H) mm) / (0.99(W) x 3.73(D) x 4.91(H) inch)

Seminar Textbook

For hands-on seminar of the CONPROSYS series [10MB]

Free Download

Request Catalog and Quote

Contact Us

  • Seminar Textbook

    For hands-on seminar of the CONPROSYS series [10MB]

    Free Download

  • Request Catalog and Quote

    Contact Us