Rich Variety of Interfaces and Excellent Lineup M2M Controller Series

The M2M Controller Series consists of two types of controllers: a stand-alone integrated type and an I/O interface expandable configurable type. The system is adaptable to a wide variety of locations, wiring methods and number of I/O channels. You can build a custom control and monitoring system to meet your specific needs.

I/O Modules

I/O interface expansion modules of the configurable type controllers.
24 VDC power is supplied by the controller to the attached I/O modules via the internal bus.

Analog Input and Output Modules

CTRM2M controller series   GWM2M Gateway series   PACPAC series   PACEdge series

Model Input Output Power Consumption Connectors Controller series
8-ch differential input,
16-bit resolution,
±10V Bus isolated
100mA(Max.) Screw terminal block
(3.81mm/0.15" pitch)
CTR
GW PAC
PAC
8-ch differential input,
16-bit resolution, 0-20mA
Bus isolated
100mA(Max.)
4-ch voltage output,
16-bit resolution, ±10V
Bus isolated
200mA(Max.)
4-ch current output,
16-bit resolution, 0-20mA
Bus isolated
200mA(Max.)

Sensor Module

Model Supported sensor / wiring method No. of CH / Isolation Power Consumption Connectors Controller series
Pt100/
Three-wire or four-wire
4ch/Bus isolated 100mA(Max.) Screw terminal block
(3.81mm/0.15" pitch)
CTR
GW PAC

Digital Input and Output Modules

Model Input Output Power Consumption Connectors Controller series
8-ch
Opto-isolated
(Compatible with current sink output)
8-ch
Opto-isolated
open-collector
(Current sink type)
100mA(Max.) Screw terminal block
(3.81mm/0.15" pitch)
CTR
GW PAC
PAC
200mA(Max.)
8-ch
Opto-isolated
(Compatible with current source output)
8-ch
Opto-isolated
(Current source type)
100mA(Max.)
16-ch
Opto-isolated
(Compatible with current sink output)
100mA(Max.)
16-ch
Opto-isolated
(Compatible with current source output)
100mA(Max.)
16-ch
Opto-isolated
open-collector
(Current sink type)
100mA(Max.)
16-ch
Opto-isolated
(Current source type)
100mA(Max.)

Relay Module

Model Input Output Power Consumption Connectors Controller series
4-ch
Relay contact output (1 pair of Form c contacts)
100mA(Max.) Screw terminal block
(50.8mm/0.2" pitch)
CTR
GW PAC
PAC

Counter Module

Model Input Output Power Consumption Connectors Controller series
Phase A/Up 1×2ch
Phase B/Down 1×2ch
Phase Z/CIR 1×2ch
General input 1×2ch
Optocoupler isolated between channels
Match signal output 1×2ch
(Opto-isolated open-collector output)
100mA(Max.) Screw terminal block
(3.81mm/0.15" pitch)
CTR
GW PAC
PAC

Serial Communication Modules

Model Transmission Scheme No. of CH / Isolation Power Consumption Connectors Controller series
RS-232C
Asynchronous serial transmission
1ch/ Bus isolated 100mA(Max.) 9-pin
D-SUB connector (s)
CTR
GW PAC
PAC
2ch / Bus isolated
Isolated between channels
200mA(Max.)
RS-422A/RS-485
Asynchronous serial transmission
(Full duplex / half duplex)
1ch / Bus isolated 200mA(Max.) Screw terminal block
(3.81mm/0.15" pitch)
2ch / Bus isolated
Isolated between channels
200mA(Max.)

LoRa Communication Modules

Model Wireless System Frequency band /
Modulation method
No. of Channels Power
Consumption
Connectors Controller
series
ARIB STD-T108 920.6~928.0MHz
LoRa
(Spread Spectrum)
15ch (at 62.5 and 125kHz bandwidth)
7ch (at 250kHz bandwidth)
5ch (at 500kHz bandwidth)
100mA(Max.) SMA connector CTR GW
  • *
    24 VDC power is supplied by the controller to the attached I/O modules via the internal bus.

Insulation Deterioration Monitoring Module for Three Phase Induction Motor + ZCT Sensor

Model The Measured Circuit No. of
measured
circuit
Inner
diameter
of ZCT
Measurement
voltage range
Measurement leakage current range
(Resolution: 0.001 mA)
Measured
insulation
resistance range
Controller
series
Overall equipment measurement
(power supply mode) / Inverter output
section measurement (inverter mode)
1ch Φ25mm
(Φ0.98”)
Line voltage
10 VAC or more,
600 VAC or less
Overall equipment measurement:
0 to less than 1A
Inverter output section measurement:
0 to less than 100 mA
Less than 1,000MΩ* CTR GW
  • *
    The guaranteed accuracy range is less than 10 MΩ

Options

Power Supplies

Model Input Output Physical
Dimensions(mm)
Mount Method Support Products
CPS-PWD-15AW12-01 85~264VAC 12VDC、
1.3A(Max.)
39.0(W)×80.0(D)×79.0(H)
(does not include protrusions)
35mm
Mountable to a 35mm
DIN rail
Integrated type controllers
CPS-PWD-30AW24-01 24VDC、
1.3A(Max.)
22.5(W)×75.0(D)×90.0(H)
(does not include protrusions)
Configurable type controllers
CPS-PWD-90AW24-01 24VDC、
3.8A(Max.)
50.0(W)×90.0(D)×90.0(H)
(does not include protrusions)
  • *
    A DC cable and a 3-pin I/O connector are included.
  • *
    AC power cable is not included. An optional AC power cable is available from Contec (IPC-ACC0DE3).

3G Antenna

Model Frequency Band Cable Length Antenna Gain Physical Dimensions Support Product
CPS-ANT-R3-01 800MHz band
2.1GHz band
3m 800MHz band: 3.09dBi
2.1GHz band: 2.48dBi
42.0(W)×42.0(D)×93.0(H)
(Not including protrusions and cable)
3G WAN Model

AC Power Cable

Model Rating Cable Length Terminals Support Product
IPC-ACCODE3 125VAC 7A 2m 3-pole round terminal Power supplies

Signal tower lights monitoring set

EnOcean wireless sensor for CONPROSYS controllers / Signal tower lights monitoring master unit set

  • The CONPROSYS controller (Individual purchase) is available from a wide selection.*Some models are excluded.
  • Any of the settings or operation can be done through a web browser.
  • The monitoring screen (Andon style display, Timeline bars, and Facility map) is ready to be used.
  • Up to 16 transmitters are configurable per Receiver.
  • An alert mail is sent to inform the user when an error occurs in real time. Mail notification can be sent up to 10 places.

Signal tower lights monitoring set

Type Model Specification
Master unit kit CPS-PAV-AES1-US Program SD card, EnOcean USB receiver, Slave unit (CPS-PAV-AE01-US)
Slave unit CPS-PAV-AE01-US Signal tower lights monitoring set

IO-Link Master

Model Supported protocols No. of CH Specification
CC-Link IE Field Basic
EtherNet/IP
Modbus TCP
PROFINET
8ch IP67 compliant

Roof Top Antenna

Model Rating Cable Length Antenna Gain Physical Dimensions Support Products
CPS-ANT-R3-01 800 MHz band
920 MHz band
2.1 GHz band
3m 800 MHz band: 3.88dBi
920 MHz band: 3.02 dBi
2.1 GHz band: 3.76 dBi
(Don’t include cable loss)
42.0(W)×42.0(D)×93.0(H)mm
(1.65"x1.65"x3.66")
(Not including protrusions and cable)
920 MHz models
3G WAN models

Connection Cable for FANUC CNC

Model Cable Length Specification Support Products
1m 20-pin to 9-pin conversion cable
(Software flow control, one touch lock type)
OPC UA server built-in modules
3m
5m

Connection Cable for Mitsubishi Electric CNC

Model Cable Length Specification Support Products
CPS-CAB-S02-1 1m 20-pin to 9-pin x 2 conversion cable
(Software flow control, one touch lock type)
OPC UA server built-in modules

Magnet (for mounting)

Model Number Support Products
Four Integrated Type Modules

Seminar Textbook

For hands-on seminar of the CONPROSYS series [10MB]

Free Download

Request Catalog and Quote

Contact Us

  • Seminar Textbook

    For hands-on seminar of the CONPROSYS series [10MB]

    Free Download

  • Request Catalog and Quote

    Contact Us

Page Top